EasyManua.ls Logo

SAJ R5-3.6K-S2 - User Manual

SAJ R5-3.6K-S2
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
R5 Series
- 1 -

Questions and Answers

  • T
    Timothy VaughanAug 19, 2025
    What to do if my SAJ Inverter shows an AC Voltage Error?
    • M
      Martin CrawfordAug 19, 2025
      If your SAJ Inverter displays an AC Voltage Error, start by checking the grid voltage and the connection between the inverter and the grid. Also, verify the inverter's on-grid standard settings.
  • W
    William SalasAug 21, 2025
    Why does my SAJ R5-3.6K-S2 show a Frequency Error?
    • T
      Timothy YangAug 21, 2025
      If your SAJ Inverter shows a Frequency Error, check the country and frequency settings for your local grid. If these settings are correct, further assistance may be needed, so contact your distributor or SAJ technical support.
  • C
    Christopher Mann DVMAug 23, 2025
    What causes a Grid Lost Error on my SAJ R5-3.6K-S2?
    • C
      Casey HernandezAug 23, 2025
      If your SAJ Inverter displays a Grid Lost Error, verify the connection status between the AC side of the inverter and the grid. If the connection is proper and the error persists, contact your distributor or SAJ technical support for further assistance.
  • T
    Toni AndrewsAug 26, 2025
    How to fix Overcurrent error on SAJ R5-3.6K-S2 Inverter?
    • Z
      zmccarthyAug 26, 2025
      If your SAJ Inverter is showing an Overcurrent error, check the connection between the inverter and the grid, and test the grid voltage for stability. If these checks are normal, contact your distributor or SAJ technical support.
  • M
    Michael JonesAug 27, 2025
    What does ISO Error mean on my SAJ Inverter?
    • T
      Thomas WhiteAug 28, 2025
      If your SAJ Inverter displays an ISO Error, check the insulation resistance of the positive and negative sides of the solar panel. Also, check if the inverter is in a wet environment and ensure the inverter grounding is secure. If these checks are normal, contact your distributor or SAJ technical support.
  • V
    Valerie HowellAug 29, 2025
    How to troubleshoot GFCI Error on SAJ Inverter?
    • M
      Meredith FieldsAug 30, 2025
      If your SAJ Inverter displays a GFCI Error, check the insulation resistance of the positive and negative sides of the solar panel. Also, check if the inverter is in a wet environment and ensure the inverter is properly grounded. If these checks are normal, contact your distributor or SAJ technical support.
  • A
    Amy BrownAug 31, 2025
    What causes High Temperature Error on SAJ Inverter?
    • A
      Alexander ThomasSep 1, 2025
      If your SAJ Inverter displays a High Temperature Error, check if the radiator is blocked and ensure the inverter is not operating in excessively high or low temperatures. If these conditions are normal, contact your distributor or SAJ technical support.
  • S
    sarahwilliamsSep 2, 2025
    What does Null line-to-earth voltage fault mean on SAJ R5-3.6K-S2?
    • M
      meganfowlerSep 3, 2025
      If your SAJ Inverter shows a Null line-to-earth voltage fault, check the stability and reliability of the AC output grounding terminal connection. If it's normal, contact your distributor or SAJ technical support.
  • R
    Rita BruceSep 4, 2025
    What to do if my SAJ Inverter has Lost Communication?
    • E
      Elizabeth HicksSep 4, 2025
      If your SAJ Inverter displays a Lost Communication error, verify the connection of the communication cables between the control board and the display board. If the connection is correct, contact your distributor or SAJ technical support.
  • Q
    qparkerSep 6, 2025
    What causes Over Bus Voltage on SAJ Inverter?
    • R
      Ryan ChapmanSep 6, 2025
      If your SAJ Inverter displays an Over Bus Voltage error, check the settings of the solar panel. A SAJ designer can assist you with this. If the settings are correct, contact your distributor or SAJ technical support.

Summary

Preface

Chapter 1 Safety Precautions

Scope of Application

Defines the SAJ on-grid inverters covered by this user manual.

General Safety Instructions

Provides crucial safety information and warnings for operating the inverter.

Target User Group

Identifies the qualified personnel authorized to install, maintain, and repair the inverter.

Chapter 2 Preparation

Preparation Safety Instructions

Details critical safety precautions to be observed before and during inverter preparation.

Symbol Explanations

Explains the meaning of various symbols used throughout the manual for safety and information.

Chapter 3 Product Information

Product Application Scope

Outlines the application scope of SAJ R5-XK-SX products in on-grid solar power systems.

Product Model Specification

Explains the naming convention and specifications for different SAJ R5 series inverter models.

Product Overview

Presents the physical dimensions and overview of the SAJ R5 series inverter models.

Technical Datasheet

Provides detailed technical specifications and performance data for SAJ R5 series inverters.

Chapter 4 Installation Instructions

Installation Safety Guidelines

Details safety instructions and warnings essential for the installation process.

Pre-installation Checks

Guides on checking the package and assembly parts before proceeding with installation.

Installation Method and Position

Determines the appropriate mounting method and optimal installation position for the inverter.

Mounting Procedures

Provides step-by-step instructions for mounting the inverter securely.

Chapter 5 Electrical Connection

Hot-line Job Safety

Outlines safety instructions for performing electrical connections, especially hot-line jobs.

Electrical Interface Specifications

Details the specifications and functions of the electrical interface ports on the inverter.

AC Electrical Connection

Provides instructions for making the AC electrical connection to the inverter.

Chapter 6 Debugging Instructions

Human-computer Interface Introduction

Introduces the human-computer interface, including LED indicators and their meanings.

Monitoring Operations Guide

Explains how to monitor the inverter's running state using the eSolar APP via Bluetooth or Wi-Fi.

Chapter 7 Fault Code and Troubleshooting

Fault Codes and Explanations

Lists and explains various error codes encountered by the SAJ inverter.

General Troubleshooting Methods

Provides general troubleshooting steps for common fault information reported by the inverter.

Chapter 8 Recycling and Disposal

Chapter 9 Contact SAJ

SAJ Warranty Policy in Australia

Standard Warranty Period Details

Specifies the standard warranty period granted for SAJ R5 series and other compatible inverters.

Warranty Extension Options

Explains how to purchase and the terms for extending the warranty period for SAJ inverters.

Warranty Claim Conditions

Describes the conditions and procedures for troubleshooting and claiming warranty service.

Service Process and Decision Making

Outlines SAJ's process for deciding how to proceed with service requests after receiving information.

Post-Warranty Service Information

Details the service fees and procedures for inverters that are out of warranty.

Warranty Exclusion of Liability

Lists circumstances under which the manufacturer's warranty is not applicable.

Warranty Card Information

SAJ R5-3.6K-S2 Specifications

General IconGeneral
ModelR5-3.6K-S2
Rated Power3.6 kW
Max. DC Input Power5.4 kW
Number of MPPTs2
Rated AC Output Power3.6 kW
Max. AC Output Power3.96 kW
Max. Output Current16 A
Rated AC Voltage230 V
Frequency50/60 Hz
THDi<3%
Max. Efficiency98.4%
Efficiency98.4%
European Efficiency97.5 %
DC ConnectionMC4
Protection DegreeIP65
Cooling MethodNatural convection
AC Voltage Range180 V - 280 V
Rated Grid Frequency50 Hz
Power Factor0.8 leading to 0.8 lagging
AC ConnectionPlug
Operating Temperature Range-25 °C ~ +60 °C
Operating Temperature-25°C to +60°C