EasyManuals Logo

SAJ VM600 User Manual

SAJ VM600
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
VM600
- 20 -
4.2 Monitoring Parameters
Parameter
Name
Minimum Unit
Priority
Address
D0.00
Running Frequency(Hz)
0.01Hz
D000
D0.01
Set Frequency(Hz)
0.01Hz
D001
D0.02
Bus Voltage(V)
0.1V
D002
D0.03
Output Voltage(V)
1V
D003
D0.04
Output Current(A)
0.01A
D004
D0.05
IGBT Module Temperature(℃)
0.1
D005
D0.06
DI Input Status
1
D006
D0.07
DO Output Status
1
D007
D0.08
Keypad Knob Voltage
0.01V
D008
D0.09
AI Voltage(V)
0.01V
D009
D0.10
Reserved
1
D010
D0.13
PLC Stage
1
D013
D0.14
Feedback Speed(Unit0.1Hz)
0.1Hz
D014