Introduction
Button functions
LCD Icon description
Technical specication
Product compliance
Safety Information
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Conformity is available on www.saluslegal.com
RT510 / RT510TX / RT510RF is a programmable room thermostat used to control room temperature.
Device launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Extended features allows us to use various operating modes
- automatic (time schedules), manual, frost protection or holiday. Before use please read this manual
carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot
located under the cover. Do not use rechargeable batteries.
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to national
and EU regulations.
RT510 / RT510TX Thermostat RXRT510 Receiver
1
6
7
8
9
4
3
2 5
1. Boost function
2. Manual Mode
3. Frost protection / Holiday Mode
4. Increase button
5. Decrease button
6. When in Manual Mode,
ON will turn the boiler on.
7. When in Manual Mode,
OFF will turn the boiler o.
8. Receiver operates in automatic mode
according to the thermostat
9. Receiver output is controlled
by the On/O slide switch.
1. Day of the week
2. Program number
3. Program indicator
4. Settings
5. Temperature measured / set
6. Boost function
7. Low battery status
8. Wireless connection with the receiver
9. Heating Mode On
10. Manual Mode On
11. Holiday Mode On
12. Frost Protection Mode On
13. Temperature unit
14. AM / PM
15. Clock
RT510 Thermostat RT510TX Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
Outputs
Voltage free
NO / COM / NC
terminals
-
Temperature range 5 - 35°C 5 - 35°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
Hysteresis ±0.25°C or ±0.5°C ±0.25°C or ±0.5°C
Radio frequency - 868 MHz
Dimension [mm] 120x96x27 120x96x27
RXRT510 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96x96x27
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
E: sales@salus-tech.com
E: techsupport@salus-tech.com
SALUS Controls is a member of the
Computime Group.
Maintaining a policy of continuous product
development SALUS Controls plc reserve
the right to change specification, design and
materials of products listed in this brochure
without prior notice.
RT510, RT510TX, RT510RF
DIP Switch Settings
RT510 Wiring diagram
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
RT510TX Wiring diagram
Setting the time
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
L
RT510TX
Thermostat
RT510TX
Thermostat
N
M
COM
NO
NC
COM
NO
NC
OR
MAX
3 (1) A
AC 230 V
RT510
Thermostat
RT510
Thermostat
L
L
NO
N
N
COM
RXRT510
Receiver
RXRT510
Receiver
AC 230 V
COM
L
L
M
N
N
NO
OR
AC 230 V
MAX
16 (5) A
RT510 Terminals description
RXRT510 Receiver terminals description
Terminal Description
1 - COM Common Terminal
2 - NC Switched Live OFF
3 - NO Switched Live ON
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Supply (230 V AC)
NO COM L N
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Press or to select the hour format.
Press the buttons SELECT and SET
together for 3 sec.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SET to conrm.
Press or to set the hour.
Press or to set the minutes.
Press or to set day of the week.
Thermostat will return to the main screen.
3 sec 3 sec
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
Programming - automatic mode
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
4
6
8
10
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
1
3
5
7
9
Use the or button to select day / days
from which you want to start programming.
Use the or button to set the hour
to start the program #1.
Use the or button to set the minutes
to start the program #1.
Use the or button
to set the temperature for program #1.
Follow steps 4-9,
to dene programs 2-6.
Press SET button to end programming.
Press the SET button to start programming.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
Press SELECT to conrm.
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
In this mode, user can set the schedules for thermostat (temperature setpoints for specic periods of
time). To do this, rstly choose programming mode: “5-2” (business days + weekend) or “24h” (each
day separately) using parameter d04 from Installer mode. Programmed schedules should use all
time periods.
The DIP Switches can be found on the rear of your thermostat.
Control feature TPI Span
Operation When TPI is selected on DIP
switch № 2, the DIP switch №
1 is functional. You can choose
the Cycles Per Hour between
a lower comfort level (6CPH)
and a higher comfort level
(9CPH).
When Span is selected
on DIP switch № 2,
the DIP switch № 1 is
not functional. The
temperature accuracy of
your thermostat is set to
± 0.25 °C.
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
TEST / PAIRING
SELECT
SET
2
3 5 6
4
1
15 14 1213
8
9
11
7
10
MON
TUE
WED
THU
FRI
SAT
SUN
MON
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
MON
TUE
WED
THU
FRI
THU
THU
THU
MONMON
MON
MON
MON
www.salus-tech.com
Issue Date: February 2018
V028
For PDF Installation guide please go to
www.salus-manuals.com
Quick Guide
868.0-868.6MHz; <13dBm

Other manuals for Salus RT510RF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Salus RT510RF and is the answer not in the manual?

Salus RT510RF Specifications

General IconGeneral
Power Supply2 x AA batteries
Frequency868 MHz
Temperature Range5°C to 35°C
DisplayLCD
Programming7-day programmable
Temperature Control Accuracy±0.5°C
Hysteresis±0.5°C
Control AlgorithmTPI
Operating ModesManual, Holiday
CompatibilityCombi Boilers
Programmable Periods6 periods per day