Index revision : C 9 6209
3.5.3.2. Using external voltage
The external voltage is between 12 and 24 Vdc.
Input impedance roughly 1 k
Ω
.
WARNING : Inputs 10 and 13 are opto-coupled inputs. They are therefore isolated from the earth.
Make sure that the 0 V of the 12 to 24 V supply is at a potential close to the earth.
3.5.3.3. In the case where
P8
= 1,
The trigger has to be connected as follows:
0 V Supply return 12 to 24 V
1 Inside
GNM
2 + 12 to 24 V dc
10 to 13
GNM
case
1 Inside
GNM
2 + 15 Vdc; 50 mA max
10 to 13
GNM
case