Please read this
manual BEFORE
installing your
inverter
Owner's
Manual
DC-AC Power
Inverter
Pure Sine Wave
PST-300-12
PST-300-24

Questions and Answers

  • C
    Christopher DayAug 13, 2025
    What to do if Samlexpower PST-300-12 Inverter does not turn on?
    • C
      Cynthia CollinsAug 13, 2025
      If the Samlexpower Inverter doesn't turn on (no LED, buzzer, or AC output), first, check the battery input circuit for continuity and ensure all connections are secure. Then, inspect the internal and external DC input fuses and replace them if they're blown. If the unit still doesn't work after replacing the fuses, it may require professional repair due to potential reverse polarity damage.
  • Z
    Zachary AguilarAug 17, 2025
    How to troubleshoot Samlexpower PST-300-12 that is not turning on?
    • K
      Kristen DickersonAug 17, 2025
      If your Samlexpower Inverter fails to power on, ensure there's voltage at the DC input terminals. Start by checking the battery input circuit for any breaks. Next, verify the internal and external DC input fuses are intact and replace any that have blown. Finally, make sure all connections in the battery input circuit are properly tightened.
  • B
    boydalbertAug 20, 2025
    What to do if AC output shuts down completely on Samlexpower Inverter?
    • J
      jriveraAug 21, 2025
      If the AC output of your Samlexpower Inverter shuts down completely, the status LED turns orange, the buzzer is on, and the green GFCI light is off, it indicates a continuous overload beyond the inverter's power rating. To resolve this, reduce the load connected to the inverter. If the issue persists after resetting and removing the load, the unit may be defective, and it is recommended to contact Technical Support. To reset the inverter, switch it off, wait for 3 minutes, and then switch it back on, ensuring the cause of the shutdown is removed beforehand.
  • R
    rebecca14Aug 25, 2025
    Why Samlexpower PST-300-12 buzzer alarm is sounded and there is no AC output?
    • C
      Christopher BenderAug 25, 2025
      If your Samlexpower Inverter buzzer sounds, the status LED turns orange, there is no AC output, and the green GFCI light is off, it signifies a shutdown due to over temperature. Verify that the fan is operational; if not, the fan control circuit might be faulty, and you should contact Technical Support. If the fan works, ensure that the ventilation slots are unobstructed and that sufficient cool air is available, and that the ambient air temperature is below 40ÂșC. Also, reduce the load to decrease the heating effect. The unit will automatically reset once the overheating cause is resolved and it cools down.
  • J
    jacob42Aug 28, 2025
    How to reset GFCI on Samlexpower PST-300-12?
    • J
      Jordan HamiltonAug 28, 2025
      If there is no AC output from your Samlexpower Inverter, the green GFCI light is off, the status LED is green, and there is no buzzer alarm, the GFCI has likely tripped. This can occur due to leakage or a Neutral to Ground bond on the load side. Check the load side circuits for any leakage or Neutral to Ground bonding and correct it. Then, press the reset button on the GFCI to reset it, ensuring that the inverter is on before resetting.
  • A
    Ashley CookAug 31, 2025
    Why Samlexpower Inverter has no AC output and the status LED is orange?
    • A
      Ashley ColeAug 31, 2025
      If your Samlexpower Inverter has no AC output, the status LED is orange, the buzzer is on, and the green GFCI light is off, it indicates a shutdown due to high input DC voltage. Ensure the voltage at the DC input terminals is less than 16.5V for 12V versions and less than 33V for 24V versions. Also, verify that the maximum charging voltage of the battery charger, alternator, or solar charge controller is below these limits. If using a solar panel, ensure it is regulated with a charge controller, especially in cold temperatures where the output may exceed safe voltage levels.
  • B
    Brian EdwardsSep 4, 2025
    How to troubleshoot low AC output voltage on Samlexpower PST-300-12 Inverter?
    • E
      Eric ReedSep 4, 2025
      A low AC output voltage (without a buzzer alarm) is caused by low input voltage at the inverter terminals when the load is near the maximum allowable power. Verify that the battery is fully charged and recharge it if necessary. Also, check that the battery cables are thick enough to carry the required current and tighten the connections of the battery input circuit. Reducing the load can also help.
  • A
    Ashley NelsonSep 7, 2025
    What to do if Samlexpower PST-300-12 Inverter status LED does not light?
    • N
      Nicholas BennettSep 7, 2025
      If the Status LED does not light when switched ON, the buzzer is off, there is no AC output voltage, and the GREEN indication light on the GFCI is OFF, it could be due to a lack of voltage at the DC input terminals or a reversed polarity. Check the continuity of the battery input circuit and ensure the fuse is intact, replacing it if necessary. When using a 12V power outlet, ensure the AC load is less than 150W and all battery input circuit connections are tight. Also, check for reversed polarity, which may have blown the fuses. Replace any blown fuses. If the unit still doesn't work, contact Technical Support.

Summary

Safety Instructions

General Safety Guidelines

Covers general safety, installation, fire hazards, electrical shock, and battery handling.

Inverter Specific Safety Measures

Addresses AC output paralleling, DC input over-voltage, reverse polarity, and external fuse.

Safety Symbols Explained

Defines the meaning of various safety symbols used in the manual.

General Information

Electrical Terminology and Definitions

Defines key electrical terms like Power, Voltage, Current, Frequency, Phase Angle, and Impedance.

Output Waveforms and Power Ratings

Explains output voltage waveforms, power ratings, and advantages of pure sine wave.

Limiting Electro-Magnetic Interference (EMI)

EMI Compliance and Reduction Methods

Discusses EMI generation, FCC compliance, and methods to reduce EMI through installation.

Powering Switch Mode Power Supplies (SMPS)

SMPS Characteristics and Inrush Current

Explains SMPS operation, inrush current, and Crest Factor.

Principle of Operation

Pure Sine Wave Output Conversion

Describes the pure sine wave output waveform and its conversion process.

Unit Layout and Components

Inverter Panel Identification

Identifies and explains the layout of the inverter's front and back panels.

Battery Related Information

Lead Acid Battery Basics and Types

Explains lead-acid battery types, construction, and electrochemical reactions.

Battery Capacity, C-Rates, and SOC

Covers battery capacity (Ah, RC), C-rates, and state of charge determination.

Battery Discharge, Life, and Connections

Discusses battery discharge limits, life, and connections.

Installation

Location and Mounting Requirements

Specifies environmental requirements, mounting orientation, and safety.

DC Side Connections and Wiring

Covers DC input voltage limits, polarity, cable, and fuse sizing.

AC Output Connections and Grounding

Discusses AC output connections, GFCI operation, and grounding.

Remote Control Wiring

Explains wiring for remote ON/OFF control using 2-wire or 1-wire.

Operation

Switching Inverter and Loads

Explains how to switch the inverter on/off and power AC loads.

Cooling Fan and Idle Current

Explains cooling fan operation and inverter's no-load power draw.

Protections

Power Surge, Overload, and Short Circuit Protection

Describes the inverter's protection against power surges, overloads, and short circuits.

Input Voltage and Other Protections

Covers low/high DC input voltage alarms/shutdowns, GFCI, and reverse polarity.

Troubleshooting Guide

Common Symptoms and Solutions

Lists common symptoms, their causes, and remedies for troubleshooting.

AC Output and GFCI Troubleshooting

Addresses troubleshooting for AC output problems and GFCI faults.

Specifications

Electrical and Performance Specifications

Details electrical specs for output, input, protections, and controls.

Compliance, Environment, and Dimensions

Covers safety compliance, working environment, and physical dimensions.

Warranty

3 Year Limited Warranty Terms

Outlines the terms and conditions of the 3-year limited warranty.

Samlexpower PST-300-12 Specifications

General IconGeneral
BrandSamlexpower
ModelPST-300-12
CategoryInverter
LanguageEnglish