What to do if there is an input signal failure in my Samson 3374-15 Controller?
- TtimothymooreAug 5, 2025
If you are experiencing an input signal failure with your Samson Controller, the suggested solution is to check the signal source and wiring.
What to do if there is an input signal failure in my Samson 3374-15 Controller?
If you are experiencing an input signal failure with your Samson Controller, the suggested solution is to check the signal source and wiring.
What to do if my Samson 3374-15 shows a sensor failure?
If your Samson Controller indicates a sensor failure, you should check the signal source and wiring.
What should I do if my Samson 3374-15 Controller shows plausibility error?
If your Samson Controller is showing a plausibility error, the suggested solution is to correct the configuration.
What should I check if there is a bus failure on my Samson Controller?
In case of a bus failure on your Samson Controller, you should check the Modbus master and connection.
What to do if my Samson Controller is blocked?
If your Samson Controller is experiencing a blockage, you should unblock the stem and valve.
What to do if my Samson Controller displays 'EEPROM error: no configuration'?
If your Samson Controller displays the error message 'EEPROM error: no configuration', you should perform the configuration again.
What to do if my Samson Controller displays 'EEPROM error: no transit time'?
If your Samson Controller displays the error message 'EEPROM error: no transit time', you should perform an initialization or transit time measurement.
Brand | Samson |
---|---|
Model | 3374-15 |
Category | Controller |
Language | English |
Details severe personal injury risks like electric shock and pressure equipment hazards.
Describes crush hazards from moving parts within the actuator.
Details methods for manually moving the actuator stem using a hex wrench or MAN mode.
Provides detailed technical specifications for different actuator versions, including electrical and mechanical data.
Guides on how to securely mount the actuator onto various valve types.
Details the process of connecting power supply and signal lines to the actuator.
Steps for installing mechanical limit contacts, including required accessories.
Instructions for installing electronic limit contacts, requiring a specific retrofit kit.
Explains how to set up Modbus-RTU communication using the RS-485 module.
Guides on switching between automatic and manual operating modes.
Describes how to select and configure different actuator applications like Positioner, PID, etc.
Explains how to access and modify parameters within the configuration level.
Details how to configure the input signal source, range, and detect signal failure.
Defines how to set the actuator's operating direction (stem extension/retraction).
Details how to set up and configure electronic limit contacts, including switching points and hysteresis.
Explains settings for detecting, removing, and protecting against valve blockage.
Step-by-step guide for initializing the actuator, including safety warnings.
Lists all possible error messages, their types, and priorities.
Provides corrective actions for various fatal errors, maintenance-demanded errors, and warnings.