EasyManua.ls Logo

Samsung AC***KNZDCH/AA - Wiring Diagram and Specifications

Samsung AC***KNZDCH/AA
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
ENGLISH
Wiring diagram
1(L)
2(N)
Indoor Unit
Outdoor Unit
Indoor Power Main power cable
Cable clmap
Cable clmap
Communication cable
V1 V2 F3 F4
1(L) 2(N)
NL
F2F1
F2F1
Between Indoor and Outdoor Connection cable Specications(Common in use)
Indoor Power supply
Communication Cable
Power Supply Max/Min(V) Indoor Power cabel
208~230V/60Hz ±10%
0.0039in² Ĺ,3wires
(2.5mm² Ĺ,3wires)
16/2 AWG shielded cable
(0.75~1.25mm²,2wires)
t Selecting wire size must comply with local and national code.
t Power supply cords of parts of appliances for outdoor use shall not be lighter than polychloroprene sheathed exible cord. (Code
designation IEC:60245 IEC 57 / CENELEC: H05RN-F or IEC:60245 IEC 66 / CENELEC: H07RN-F)
t 4DSFXTPOUFSNJOBMCMPDLNVTUOPUCFVOTDSFXFEXJUIUIFUPSRVFMFTTUIBOLHGtDN
t Since it has the external power supply, refer to the outdoor unit installation manual for MAIN POWER.
Terminal Block SPEC (Indoor)
AC POWER : M4 SCREW COMMUNICATION : M4 SCREW
0.43(8.4)
0.51(9.5)
0.43(8.4)
0.51(9.5)
0.7(10.0)
0.7(10.0)
Tightening Torque
M4 12.0~18.0 (kgf·cm) 0.86~1.3.0 (lbf·ft)
WARNING
In case of extending the electric wire, please
DO NOT use a round-shaped pressing socket.
- Incomplete wire connections can cause
electric shock or a re.
jhjGvktG}Tho|ptuv{jvkllunUGGGX^ YWX]TXWTX_GGG㝘㤸GXXaYXaX[