19
ENGLISH
Power supply wiring with accessory electric heat kit
1. Before wiring work, you must turn o all power source.
2. Only copper power cables should be used.
3. Remove the blower and control box access panel (door).
4. Install the cable connectors on the 7/8” diameter holes on the
left side of the control box.
5. Connect the included power pigtail leads with ring
connectors (included with heat kit) to 1(L) and 2(N) terminals
located on the right side of the control box.
6. Route the power pigtail leads through the control box
opening pictured below and route to the left side of the
control box for connection to the heat breakers in a later step.
Power conduit connection openings
7. Swing the hinged control plate outward exposing the back side of the control box. Remove the screws holding the electric
heat kit block o plate. Save the screws.
8. Carefully pass the accessory heating element through the rectangular opening in the discharge of the air handler and
secure the heating element with the screws from step 8. Heating element support rod must be seated in the hole on the
opposite side of the discharge.
9. Install the breakers at the front-left of the control box.
10. Connect the power pigtail leads that are connected to 1(L) and 2(N) to the bottom of the breakers.
11. Insert the power wires through the holes in the casing and through the cable connectors.
12. In order to use heating function, you need change the installation option code. Set SEG10 to 1. For more information on
changing the option code, refer to “Setting an indoor unit installation option on page 38.