Blower CFM tables
AC030KNZDCH/AA
HP : 1/2Default motor
taps:High / Mid /Low =
3/2/1
Motor Tap P(inwg) CFM Motor Tap P(inwg) CFM
1
0.1 891
4
0.1 1160
0.2 848 0.2 1126
0.25 826 0.25 1109
0.3 805 0.3 1092
0.4 758 0.4 1055
0.5 710 0.5 1019
0.6 658 0.6 982
0.7 605 0.7 943
0.8 547 0.8 904
0.9 486 0.9 864
1 419 1 823
2
0.1 987
5
0.1 1314
0.2 951 0.2 1282
0.25 932 0.25 1266
0.3 914 0.3 1251
0.4 875 0.4 1217
0.5 834 0.5 1183
0.6 790 0.6 1149
0.7 742 0.7 1113
0.8 690 0.8 1076
0.9 633 0.9 1039
1 567 1 1000
3
0.1 1060
= Default Setting
0.2 1025
0.25 1009
0.3 990
0.4 954
0.5 915
0.6 875
0.7 832
0.8 787
0.9 737
1 684








!
     !     