13. Installation
13-1. Indoor unit
ACMNTDCH
Installation plate (1)
ߡߤߡࢥߡߤߧ
ŵʪͱϩʪʀͱϩθͱ࣍ߢ࣎
ŵʪͱϩʪʀͱϩθͱɵɇϩϩʪθц࣍ߣ࣎ ƸϑʪθđɇЇɇ࣍ߢ࣎
ÃϑϩɇɇϩͱđɇЇɇ࣍ߢ࣎ ŵʪͱϩʪAͱϩθͱ²ͱʒʪθ࣍ߢ࣎
đߥуߢߧ
ƟɇΧΧʪʒƊʀθʪиϑ࣍ߣ࣎
Step 1.3 Drilling a hole through the wall
Before fixing the installation plate to a wall and then fixing the indoor unit to
the installation plate, a window frame, or a gypsum board, you must determine
the position of a hole [with 2.56 inch (65 mm) inner diameter] through which
the pipe bundle (consisting of power and communication cables, refrigerant
pipes, and drain hose) will pass and then drill that hole.
1 Determine the position of a 2.56 inch (65 mm) hole in consideration of
the possible directions of the pipe bundle and the minimum distances
between the hole and the installation plate.
ťͱϑϑɵʪʒθʪʀϩͱϑͱ˙ϩ˵ʪΧΧʪɵЇʒʪ
Left
Right
Rear right or left
Bottom right
CAUTION
• If changing the pipe direction from left to right, do not drastically bent it
but slowly turn it in the opposite direction as shown. Otherwise, the pipe
may be damaged in the process.
Unit : inch (mm)
đͱʒʪ ABCD
AC018MNADCH 1.42 (36) 7.48 (190) 3.19 (81) 1.42 (36)
AC024MNADCH 1.30 (33) 4.33 (110) 4.33 (110) 1.30 (33)
Pipe bundle hole: Ø 2.56 inch (65 mm)
đЇʒϑϩɇʀʪϑɵʪϩиʪʪϩ˵ʪ˵ͱʪɇʒϩ˵ʪϑϩɇɇϩͱΧɇϩʪ
B
A
D
C
Pipe bundle hole
A
C
B
D
FE
Unit : inch (mm)
đͱʒʪ ABCDEF
AC030/036MNTDCH
6.14
(156)
2.64
(67)
14.33
(364)
1.36
(34.5)
2.54
(64.5)
0.77
(19.5)
Pipe bundle hole: Ø 2.56 inch (65 mm)
đЇʒϑϩɇʀʪϑɵʪϩиʪʪϩ˵ʪ˵ͱʪɇʒϩ˵ʪϑϩɇɇϩͱΧɇϩʪ
Pipe bundle hole
2 Drill the hole.
CAUTION
• Be sure to drill only one hole.
• Make sure that the hole slants downwards so that the drain hose slants
downwards to drain water well.
Wall
Drain hose
Indoor unit
Ɵ˵ʪ˵ͱʪϑɇϩϑʒͱииɇθʒϑ