EasyManua.ls Logo

Samsung AC071MN4PKH - Page 78

Samsung AC071MN4PKH
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
4-38
Yes
Indoor/outdoor communication error (1 min.) (Error Code: E202)
(cont.)
Continue
Check the communication circuit of the Main PCB of the outdoor unit.
1. Is there a fault in communication IC?
2. Is there a fault in TVS-Diode?
Communication IC Measuring (Port)
Steady-state Measuring Value
Remark
COM 1(RED)
#6 - #5 0.9k ~ 1.2k
Measuring after separating the
communicatio
connection
#7 - #5 0.9k ~ 1.2k
#8 - #5 4.7Vdc ~ 5.3Vdc
TVS-Diode Measuring Steady-state Measuring Value
Both ends of diode 1k or above
Measuring
Part
Communication IC Measuring Part
(Circuit Diagram)
Example of Measuring
Communication IC
Example of Measuring
TVS-Diode
Location
Measuring
Point
#5-GND, #6- Communication A, #7-
Communication B, #8-Vcc