EasyManua.ls Logo

Samsung AC071MN4PKH - Page 89

Samsung AC071MN4PKH
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
4-49
IPM over(Over Current) error (Error Code : E464)(cont.)
Yes
1. Replace the compressor wire. ĺ Power ON. ĺ
Check normal startup. ĺ End the service.
2. Replace the compressor wire. ĺ Power ON. ĺ
Check normal startup. ĺ End the service.
3. Replace the compressor wire. ĺ Power ON. ĺ
Check normal startup. ĺ End the service.
No
1. Did compressor
wires assembled
in the appropriate color?
(U:Red, V:Blue, W:Yellow) ĺ Check for
disconnections of PCB and COMP.
2. Is the terminal in the compressor wire
housing firmly assembled?
3. Is there any fault of compressor
wires in disconnection
or cutting?
Replace the PCB.
Continue
Yes
E46 Error-related, EMI / outdoor unit Main / Indoor unit Main PCB do not replace!
ĺ This error is related to the Inverter PCB. (Not related to the above PCB)
Ensure that the service valve is open!
ĺ When the service valve is closed, the defects may be caused by differential
pressure when starting the compressor.
W
V
U
W
V
U
W
V
U
W
V
U
[RC6666HXH series]
[RC0606666/RC0726666 series]
[RC0906666/RC1006666/
RC1106666/ RC1306666/
RC1456666/RC1606666 series]
PCB connecting connector PCB connecting connector

Table of Contents

Other manuals for Samsung AC071MN4PKH

Related product manuals