Troubleshooting
4-22 Samsung Electronics
Suction temperature sensor is detached from the sensor holder on the pipe. (E-269)
Outdoor unit Display E-269
Indoor unit Display
Duct, Cassette (1 / 2Way), Console, Ceiling
Operation Defrost Timer Fan Filter / MPI
× ×
Cassette (4Way / Mini 4Way)
Operation Defrost Timer Filter
×
Duct, Cassette (1/2 Way), Console, Ceiling
Operation Timer Turbo 24°C 27°C
× ×
: ON
: Flash ×: OFF
Judgement Method
•JudgmentMethod:Differenceofsuctiontemperatureofcompressorstarting
verge and suction temperature that is on present operation : If less than 2 °C for
30 minutes to keep.(Judgment at heating operation only)
Cause of problem •Suctiontemperaturesensorbreakaway/defective.
Is Suction sensor
and sensor Holder
accurately
attached?
Re-insert sensor OR and re-attach sensor holder.
Yes
No
Is Suction sensor
resistance value
reasonable?
(Refer to E231 )
Defective sensor : Replace sensor.
No
Yes
Complete