EasyManua.ls Logo

Samsung AR09TXFCAWKNEU - Wire Connecting the Indoor Unit Terminal Blocksl

Samsung AR09TXFCAWKNEU
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
84
SAMSUNG ELECTRONICS
8-5 Wire connecting the indoor unit terminal blocks
1. Terminal press of Ring terminal shall be set facing up before connecting wire.
Is inverted Terminalhasbeencut.
2. There shall be no empty space between Ring terminal and Screw after Clamp.
If not, there exists a possibility of re which can be caused by electric heat in the connecting part.
1,2 : Good
3 Bad : Ring terminal is connected reversely
4 Bad : Not clamped Screw
5 Bad : In the gap between Ring terminal & Screw
6 Bad : Unused Ring Terminal

Other manuals for Samsung AR09TXFCAWKNEU