19
English
Installation
Step 2-6 Connecting the drain hose
1 In Step 2-2, step 3 you determined the exit position for the
piping bundle. If using the right, bottom, or right rear exit,
change the drain hose connection from the right to the
left so that the drain hose will lie along the inside of the
unit and exit to the right.
Drain pan outlet
Rubber cap
CAUTION
• Be careful not to puncture the plug with the
screwdriver when installing it.
2 If using the left, right, or bottom exit, pass the drain hose
through the selected knockout.
Drain hose
Refrigerant pipes
(assembly pipe)
Connection hose
3 Connect a 15.88 mm ID extension drain hose to the main
drain hose.
CAUTION
• If the diameter of the connection hose is smaller than
the product’s drain hose, leakage may occur.
40~45 mm
Drain hose (A)
Drain hose
Vinyl tape
Extension drain hose (B)
Extension drain hose
20 mm or more
Foam insulation
40~45mm
4 Do not box in or cover the drain hose connection. It must
be accessible for testing later in the installation process
and for future servicing.
5 If the drain hose is routed inside the room, insulate the
hose so that dripping condensation does not damage the
furniture or floors.