EasyManua.ls Logo

Samsung AR18KSWSJWKNCV - Comp Vlimit Error

Samsung AR18KSWSJWKNCV
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics 10-23
10-2-20
Comp Vlimit error
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1 LED2 LED3
{
E465 Comp V_limit/I_limit Error
Outdoor display
O
{
Comp V_limit/I_limit Error
O
LED ON
LED BLINKING
{
LED OFF
1. Checklist :
1) Is the IPM Shunt("A") resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
MODEL "A"
AR12(09)HSFSHWK R410,R411,R412
AR18HSFSHWK R413,R414,R415
YES
YES
YES
YES
Is the O.C error occurred?
Is the connection
of compressor wire is
normal?
Is the Comp Vlimit error occurred again?
Is the condition of
indoor/outdoor temperature
normal load?
Restart after power off.
NO
NO
NO
NO
Terminate the service
Connect the comp wire normally
Terminate the service
Restart after returning to the normal load
Is the O.C error
occurred again?
Terminate the
service
YES
NO

Table of Contents