EasyManua.ls Logo

Samsung AR18KSWSJWKNCV - Other Operational Errors

Samsung AR18KSWSJWKNCV
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10-20 Samsung Electronics
10-2-17
I_trip error, PFC over current
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1 LED2 LED3
E462 AC Input I_Limit Trip Error
{
Outdoor display
O
O
AC Input I_Limit Trip Error
O
LED ON
LED BLINKING
{
LED OFF
1. Checklist :
1) Is the PFC Shunt("A") resistance value correct? Check the resistor is opened
2) Is the condition of surrounding temperature abnormal overload?
3) Is there any problem as like the temperature sensor separation or measurement value error?
4) Is the interphase resistance of compressor normal?
2. Troubleshooting procedure
MODEL "A"
AR12(09)HSFSHWK R425,R426
AR18HSFSHWK R807,R808,R809
AR24HSFSHWK "-"
Restart after power off.
Exchange the Outdoor PBA
Is the condition of indoor/outdoor
temperature normal load?
Is the position of
temperature sensor and the sensing
value normal?
Is the connection
cable for the compressor and power
terminal normal?
NO
NO
NO
Restart after returning to the normal load
Is the I_trip error
occurred again?
Terminate the
service
Correct the sensor position or
exchange the sensor
Correct the cable connection
YES
YES
YES
YES
NO