Samsung Electronics 10-11
10-2-10 Outdoor Fan motor error
Indoor display
3-LED DISPLAY
7-SEG DISPLAY
DESCRIPTION
LED1 LED2 LED3
E458 Outdoor fan error
{
Outdoor display
O
{{
Outdoor fan error
O
LED ON
LED BLINKING
{
LED OFF
1. Checklist :
1) Are the input power voltage and the power connection correct?
2) Is the motor wire connected to the outdoor PBA correctly?
3) Is there no assembly error or non-assembly in the terminal of motor wire connector?
4) Is there no obstacle at the surrounding of motor and propeller?
2. Troubleshooting procedure
NO
YES
Power off and Separate the Fan motor wire
from "A" on Outdoor PBA
Exchange the Fan
motor
YES
YES
NO
YES
YES
Does the fan rotate?
Is the fan error appeared again?
Is there short among
each pin #1#6
Is the voltage of "A" #1-#3 over 250Vdc
Is the voltage of "A" #3-#5 and
#3-#6 with in 1Vdc15Vdc during
the operation?
Restart after power off.
Reassemble the fan wire and input the power again
PBA problem or Motor problem
Change the PBA first and check the operation
Exchange the Fan motor
NO
NO
NO
Terminate the
service
Follow the check procedure of outdoor unit
power supply error check
Exchange the Outdoor PBA
MODEL "A"
AR12(09)HSFSHWK CN901
AR18HSFSHWK CN901
AR24HSFSHWK CN90

Table of Contents