13
SAMSUNG ELECTRONICS
3. Alignment and Adjustments
3-1 Test Mode
• How to Approach Test Mode
You can approach the test mode by pressing the on/off switch of indoor unit for 5 seconds.
• Test mode operation option
After installing the air conditioner, check whether each subordinate is normally operated or not by operating the
test mode.
●
When an Error occurs, display the Error Mode.
●
Operation Mode : Cool mode. operate the cool mode by operating the compressor by force without the compressor
ON/OFF according to the set temperature/indoor temperature. (Do not follow the antifreeze control)
●
Up-down louver : Up-down swing mode
●
Indoor Fan : Turbo
• Because the teat mode operate the cool mode by force not related to the set temperature / indoor
temperature, check whether each subordinate is operated normally or not after completing
installation and must turn off the power of the air conditioner.