Samsung Electronics32
Troubleshooting
6-2-2 Room temperature sensor failure
No
ASS'Y Sensor Replace
SENSOR Resistance Value : 20˚C-12.09k
SENSOR Resistance Value : 30˚C-8.31k
SENSOR Resistance Value : 35˚C-6.94k
SENSOR Resistance Value : 40˚C-5.83k
Ye s
No
No
Detach the assembly sensor from the
ASS'Y PCB CN43 connector and measure
the sensor resistance with an ohmmeter (tester).
Connect the sensor to CN43,
supply power, and measure the voltage of
#1 and #2 of the CN43 connector.
MICOM Error or Connector(CN43) check
Is the sensor resistance value
10K ±3% at the room temperature
of 25˚C?
Ye s
Poor ASS'Y PCB Replace
Below 0.5V?
Ye s
Poor ASS'Y PCB Replace
Over 4.9V?
Error Mode
LAMP 7-segment Display
Indoor unit room temperature sensor error(open or short)