EasyManua.ls Logo

Samsung AS12HPBX - 6-4 Main Part Inspection Method

Samsung AS12HPBX
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Samsung Electronics40
6-4 Main Part Inspection Method
Room Temperature Sensor
Room Fan Motor
Outdoor Fan Motor
Stepping Motor
Measure resistance with a tester
Normal At the normal temperature 37k~ 8.3k(-7˚C~+30˚C)
*Refer to Table 6-3-4.
Abnormal , 0
...
Open or Short
Measure the resistance between terminals of the connector (CN72) with a tester.
Normal At the normal temperature (10˚C ~ 30˚C)
Abnormal , 0
...
Open or Short
Measure the resistance between motor wires with a tester.
Normal At the normal temperature (10˚C ~ 30˚C)
Abnormal , 0
...
Open or Short
Measure the resistance between the red wire and each terminal wire with a tester.
Normal About 300 at the normal temperature (20˚C ~ 30˚C)
Abnormal , 0
...
Open or Short
Breakdown Inspection MethodPart
Compare terminal Resistance Remark
Yellow, Blue 404.4 ± 10% Main
Yellow, Red 340 ± 10% Sub
Compare terminal Resistance Remark
Yellow, Red 360 ± 10% Main
Black, Yellow 328 ± 10% Sub
DB98_20429A(1)_1 12/24/04 10:55 AM Page 40