EasyManua.ls Logo

Samsung CLX-6220FX - Page 91

Samsung CLX-6220FX
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alignment & Troubleshooting
Service Manual
4-21
Samsung Electronics
Code LCD Display Meaning State Displayed
106-0032 0032-C Deve AC Cyan Deve bias AC voltage on at normal drive level On[Off]
106-0033 0033-M Deve AC Magenta Deve bias AC voltage on at normal drive level On[Off]
106-0034 0034-Y Deve AC Yelllow Deve bias AC voltage on at normal drive level On[Off]
107-0000 0000-Y THV Bias Yellow THV bias voltage on at normal drive level On[Off]
107-0010 0010-M THV Bias Magenta THV bias voltage on at normal drive level On[Off]
107-0020 0020-C THV Bias Cyan THV bias voltage on at normal drive level On[Off]
107-0030 0030-K THV Bias Black THV bias voltage on at normal drive level On[Off]
107-0040 0040-Y THV Bias R Detect what the THV value is on the THV Roller Numeric 3 digits
107-0120 0120-ATTR+ Bias ATTR plus bias voltage on at normal drive level On[Off]
107-0140 0140-ATTR- Bias ATTR Minus bias voltage on at normal drive level On[Off]
107-0150 0150-PTL Pre Transfer Lamp 1 On[Off]
107-0160 0160-Erase Lamp Erase Lamp 1 On[Off]
109-0000 0000-Temp A Detects what the temperature A is on fuser. Numeric 3 digits
109-0010 0000-Temp B Detects what the temperature B is on fuser. Numeric 3 digits
109-0030 0030-Fuser Mot Fwd Fuser Motor Forward On/Off On[Off]
109-0040 0040-Fuser Fan Run Fuser Fan Motor On/Off On[Off]
109-0050 0050-Fuser Bias Fuser bias voltage on at normal drive level On[Off]
109-0090 0090-Fuser Power On It controls temperature of fuser as 180 degrees. On[Off]
110-0000 0000-LSU Motor1 Rdy Detects if LSU motor1 runs at normal speed. High[Low]
110-0010 0010-LSU Motor2 Rdy Detects if LSU motor2 runs at normal speed. High[Low]
110-0060 0060-LSU Motor1 Run LSU Motor1 On/Off On[Off]
110-0070 0070-LSU Motor2 Run LSU Motor2 On/Off On[Off]
110-0080 0080-LD Power1 LSU LD1 Power On/Off (yellow) On[Off]
110-0090 0090-LD Power2 LSU LD2 Power On/Off (magenta) On[Off]
110-0100 0100-LD Power3 LSU LD3 Power On/Off (cyan) On[Off]
110-0110 0110-LD Power4 LSU LD4 Power On/Off (black) On[Off]
112-0000 0000-ACR Exec Now Start Auto Color Registration On[Off]
112-0010
0010-Manu Regi
Clear
Clear Manual Offset Value of Color Regi. On[Off]

Table of Contents