9-2 Refrigerating Cycle Diagram
*Allowable pipe length : Max. 30m
*Allowable drop distance : Max. 15m
Indoor Unit Outdoor Unit
Amount of refilling per extension length of 1m; When extending the pipe length by more than 7.5m,add “Q” of refrigerant for extrameter.
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Cooling
Heating
Gas leak check point
Liquid pipe
Gas pipe
Compressor
Muffle
Accumulator
3-Way valve
Expansion
valve
Filter
Filter
3-Way valve
24524(1)_156/10/37:09PMPage4-26
Samsung Electronics 9-3
Model
UH070EAMC 40 g/m
Q (R410A)
UH052EAMC
25 g/m
UH094EAM1C
60 g/m