Performing Leak Tests
3-8. Performing Leak Tests
Before completing the installation (insulation of the hose and piping), you must check that there are no gas
leaks.
To check for gas leaks on the... Then, using a leak detector,
check the...
Indoor unit Flare nuts at the end of sections A
and B.
Outdoor unit Valves on sections C and D.
C
D
A
B
CAUTION
The CH✴✴CA models need a new refrigerant, R407C.
Thus, when refrigerant leakage occurs in use, you must purge and
make vacuous with a vacuum pump before adding the refrigerant.
Then put the optimal quantity of refrigerant newly.
In addition, the refrigerant must be added in liquid phase.