56 | SAMSUNG
SPECIFICATION OF CONTROL MODULE
4
Dehumidifying Control
4-3. Dehumidifying Control
4-3-1. Operation pattern
4-3-2. Operation specification
Œ
On/Off time as per the dehumidifying mode
´
COMPor and indoor fan operation cycle
COMPor and
Indoor fan
Operation cycle (minutes)
ON time
OFF time
II-Mode
5 minutes
5 minutes
I-Mode
6 minutes
4 minutes
III-Mode
3 minutes
6 minutes
IV-Mode
COMPor
OFF