5-1. Refrigerating Cycle Block Diagram
5. Diagrams
Cassette Type
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Gas Side
Muffler
High Pressure switch
Compressor
Accumulator
4-Way Valve
Reservior
Capallary Tube
Capillary
Tube
Check
Valve
Cooling
Heating
Gas leak check point
Capallary Tube
Capillary Tube
Check Valve
Heat
Exchanger
(Evaporator)
Heat
Exchanger
(Condenser)
Gas Side
Muffler
High Pressure switch
Compressor
Accumulator
4-Way Valve
Reservior
Capillary
Tube
Cooling
Heating
Gas leak check point
Capallary Tube
Capillary Tube
Check Valve
3-Way Valve
3-Way Valve
3-Way Valve
DRIER
3-Way Valve
ACH1800E, ACH2400E, CH18ZA, CH24ZA
CH18CA, CH24CA
Indoor Unit Outdoor Unit
*Allowable pipe length : Max. 30m
*Allowable drop distance : Max. 15m
Indoor Unit Outdoor Unit
*Allowable pipe length : Max. 30m
*Allowable drop distance : Max. 15m
*Amount of refilling per extension length of 1m;
When extending the pipe length by more than 5m, 40gr(50gr: Outdoor Unit is higher than Indoor Unit) of R-22
refrigerant should be refilled per extension length of 1m.
*Amount of refilling per extension length of 1m;
When extending the pipe length by more than 5m, 50g of R-407C refrigerant should be refilled per extension length of 1m.
62 | SAMSUNG
DIAGRAMS
5