26 _ Troubleshooting
4-2. TEST MODE
 Continuous run mode
Continuous run mode:
1. PressDryLevel+Signal(MixedLoadBell)for7secduringPowerOnState(normalusermode).
2. OnceinContinuousRunMode,“cc”andtheremainingtimewillblinkinthe7-Segment.
3. ThepreviouscyclewillrestartduringContinuousRunModeuntilthemodeisdeactivated.
4. DuringContinuousRunMode,pressDryLevel+Signal(MixedLoadBell)for7secondstogobacktonormaluser
mode.“cc”willgooffandtheremainingtimewillkeepblinking.
 Special test mode
Denitionofspecialtestmode:
• ThedryermustbeonbeforeServiceModecanbeentered.
• PressSignalandTempbuttonsfor3seconds,oruntil3beepsareheard.
• ThemachinewillnowbeinServiceMode.
• UponentryintoServiceMode,theSensorBarTouchDatawillbeshown(DefaultSpecialTestMode).
How to enter:
• ToenterSpecialTestModepressSignalandTempButtonsfor3secondsoruntilthecontrolbeep.
(sameforallFrontiermodels.)
 Cycle count mode
Denitionofcyclecountmode:
• WhileinServiceModepressingtheWrinklePreventbuttonwillputthedryerintothecyclecountmode
• Cyclenumberexecutedwilldisplay.
How to enter:
• ToenterSpecialtestmode,whileinservicemode,presstheWrinklePreventbuttonuntilthecontrolbeep.(samefor
allFrontiermodels.)
 Software version mode
Denitionofsoftwareversionmode:
• WhileinServiceModepressingtheTempbuttonwillputthedryerintothesoftwareversionmode
How to enter:
• ToenterSpecialTestModepressTempButtonuntilthecontrolbeep.(sameforallFrontiermodels.)
ex)Incaseof“U105”,U0meansmajorversion“v1“05meansminorversion“05”
Poweronstate
(Normalusermode)
Dry Level + Signal
(Mixed Load Bell) 7Sec
Continuous run mode