4
Data Display Mode
Denition of Temperature Display Mode:
- Display Mode 0 : Temperature data(Celsius)
- Display Mode 1 : Average Touch Sensor data for 1 minute
- Display Mode 2 : Average Temperature(Celsius) data for 1minute
How to Enter:
- WithPowerOn,pressAdjustUpKey+AdjsutDownKeyfor7secondsuntilitsendsouta
beeping sound .
- If not pressed any keys for 5 minutes, it will be set back from Data Display Mode
- IfpressingAdjustUpKeyinthismode,DisplayModeIDwillbeincreased.
- If pressing AdjustDown Key in this mode ,Display Mode ID will be decreased.
• Converting °C
°F
Celsius(°C) -30 -10 10 30 50 70
F =9/5C + 32
Fahrenheit(°F) -22 14 50 86 122 158
System Check Mode
Denition of System Check Mode:
- “t2”willdisplay.
- System Check Mode(t2 mode) Progress Function Performed Start/Pause
Motor(CW)RelayOn
HeaterRelayOn
HeaterRelayO,Motor(CW)RelayO
How to Enter:
- WhileinPowerO,pressingtheDryLevel+Powerkeyssimultaneouslywillputthedryerinto
the System Check mode
ALIGNMENT AND ADJUSTMENTS
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
F900A DRY_DV50F_TECH MANUAL_DC68-03171D_EN(邀请翻译成法语).indd 4 2013-1-21 13:55:30