Essential
2. Specification
20
Type DVM S DVM S
Model Name AM340MXVDGH/ET AM360MXVDGH/ET
Outdoor unit module 1 AM160MXVDGH/ET AM180MXVDGH/ET
Outdoor unit module 2 AM180MXVDGH/ET AM180MXVDGH/ET
Outdoor unit module 3 - -
Outdoor unit module 4 - -
Wiring
connections
Transmission Cable mm
2
0.75 0.75
Remark -
F1, F2 F1, F2
Power supply intake - Both indoor and outdoor unit Both indoor and outdoor unit
Refrigerant Type -
R410A R410A
Factory Charging kg
8.4 x 2 8.4 x 2
tCO
2
e
35.08 35.08
Sound Sound Pressure Cooling dB(A)
67 67
Heating dB(A)
70 70
Sound Power dB(A)
87 87
External
Dimension
Net Weight kg
253.0 x 1 + 255.0 x 1 255.0 x 2
Shipping Weight kg
273.0 x 1 + 275.0 x 1 275.0 x 2
Net Dimensions (WxHxD) mm
(1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2
Shipping Dimensions (WxHxD) mm
(1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 2
Operating
Temp. Range
Cooling ℃
-5 ~ 48 -5 ~ 48
Heating ℃
-25 ~ 24 -25 ~ 24
NOTE
• Specification may be subject to change without prior notice.
• Specification comply with EN14511.
1) Capacities are based on (Equivalent refrigerant piping 7.5m, Level differences 0m);
- Cooling : Indoor temperature 27°C DB, 19°C WB / Outdoor temperature 35°C DB, 24°C WB
- Heating : Indoor temperature 20°C DB, 15°C WB / Outdoor temperature 7°C DB, 6°C WB
Eurovent certified
2) Allowed combination ratio of the total rated indoor unit capacity over the rated outdoor unit capacity is
50~130%.
3) Sound pressure level is obtained in an anechoic room.
- Sound pressure level is a relative value, depending on the distance and acoustic environment.
- Sound pressure level may differ depending on operation condition.
- dBA = A-weighted sound pressure level
- Reference acoustic pressure 0 dB = 20uPa
4) Sound power level is an absolute value that a sound source generates.
- dBA = A-weighted sound power level
- Reference power : 1pW
- Measured according to ISO 3741
5) Sound values of multi combination are theoretical values based on sound results of individual installed units.
6) These products contain R410A (GWP=2,088) which is fluorinated greenhouse gas.
7) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under.
(If the level difference is higher than 50m, make a decision by PDM kit installation Guide software whether
the PDM kit should be installed or not.)
- PDM kit: Pressure Drop Modulation kit
When the outdoor unit is below the indoor unit & the level differences are 40m or more, contact your local
dealer for more information.
• In case you want to know more information regarding capacity and correction, please refer to capacity table
TDB on pvi.samsung.com site.