THE FEATURE OF PRODUCTAIR CONDITIONER
Multi Inverter(Free Joint Multi) Series
– Variable Indoor Unit Combination(Free Joint Multi)
– Multi Inverter(Free Joint Multi) Series delivers
comfort to 2~4 rooms with a Single Outdoor Unit
– Smart & Low noise outdoor units in any condition.
Energy Saving
– High Efficiency DC inverter and BLDC Comp.
– Smart Inverter Control algorithm.
TBR Sine-Wave Compressor & Sine Wave Controller.
Convenient Installation
– 485 non Polarity / Auto addressing
– Easy checking system condition by 7-segment
Various Indoor Unit
– Vivace, MSP duct, Console, 1 way, Slim duct,
Mini 4 way, Neo Forte, MB
Space Saving & Environmental Friendly
– Compact & Light Outdoor Unit
– Slim and Quiet Indoor Units
SERVICE
Manual
Refer to the service manual in the GSPN(see the rear cover) for the more information.
FREE JOINT
MH020FVEA
MH023FVEA
MH026FVEA
MH035FVEA
MH052FVEA
MH020FNEA
MH026FNEA
MH035FNEA
MH052FNEA
MH023FBEA
MH026FBEA
MH035FBEA
MH052FBEA
MH026FKEA
MH035FKEA
MH030FMEA
MH035FMEA
MH052FMEA
MH023FEEA
MH026FEEA
MH035FEEA
MH052FUEA
MH026FJEA
MH035FJEA
FIXED
MH18VF1-09
MH19VF1-07
MH19VF1-12
FREE JOINT
MH040FXEA2B
MH050FXEA2B
MH060FXEA3B
MH070FXEA4B
MH080FXEA4B
FIXED
MH18VF1X
MH19VF1X
INDOOR UNIT OUTDOOR UNIT
MULTI AIR CONDITIONER

Other manuals for Samsung MH050FXEA2B

Question and Answer IconNeed help?

Do you have a question about the Samsung MH050FXEA2B and is the answer not in the manual?

Samsung MH050FXEA2B Specifications

General IconGeneral
TypeAir conditioner outdoor unit
Multi-split-
Product colorWhite
Inverter technologyYes
Refrigerating mediumR410A
Cooling capacity (max)18425 BTU/h
Cooling capacity (min)5118 BTU/h
Heating capacity (max)21837 BTU/h
Air conditioner functionsCooling, Heating
Cooling capacity in watts (max)5400 W
Cooling capacity in watts (min)1500 W
Heating capacity in watts (max)6400 W
Cooling energy efficiency (EER, W/W)3.76
Heating energy efficiency (COP, W/W)4.07
Operating temperature (cooling) (T-T)-5 - 43 °C
Operating temperature (heating) (T-T)-15 - 24 °C
Current13.5 A
AC input voltage220-240 V
AC input frequency50 Hz
Energy efficiency class (cooling)A
Power consumption (cooling) (max)1330 W
Power consumption (heating) (max)1400 W
Hourly energy consumption (cooling)- kWh
Indoor unit width- mm
Outdoor unit depth310 mm
Outdoor unit width880 mm
Outdoor unit height638 mm
Outdoor unit weight53000 g
Outdoor units quantity1
Outdoor unit noise level50 dB

Summary

MULTI AIR CONDITIONER

Indoor Unit Model Overview

Lists available indoor unit models.

Outdoor Unit Model Overview

Lists available outdoor unit models.

Product Feature Highlights

Highlights key product capabilities and benefits.

Precautions

Installing the Air Conditioner

Safety guidelines for proper installation of the unit.

Power Supply and Circuit Breaker

Electrical safety precautions for power connection.

During Operation

Safety guidelines and precautions for normal unit operation.

Disposing of the Unit

Environmental guidelines for unit disposal.

Other Precautions

General safety notes and warnings for handling.

Product Specifications

Detailed Product Features

Detailed product features overview and benefits.

Product Specification Tables

Technical specifications for various indoor and outdoor units.

Comparative Specifications

Comparative Model Overview

Side-by-side comparison of different air conditioner models.

Comparative Model Details

Detailed comparative tables for model specifications.

Accessory and Option Specifications

Indoor Unit Accessories List

Lists all standard accessories included with indoor units.

Outdoor Unit Accessories List

Lists all standard accessories included with outdoor units.

Transmitter Unit Accessories List

Lists accessories specifically for the transmitter unit.

Alignment and Adjustments

Error Code Troubleshooting

Troubleshooting error codes and indicator lights for indoor units.

Setting Unit Options

Procedure for setting unit operational options via remote control.

Model Option Code Mapping

Table mapping specific models to their configuration option codes.

Disassembly and Reassembly

Disassembly Tools Required

Lists essential tools required for unit maintenance.

Outdoor Unit Disassembly Guide

Step-by-step guide for disassembling the outdoor unit.

Exploded Views and Parts List

Indoor Unit Exploded Views and Parts

Diagrams and parts lists for various indoor unit models.

Outdoor Unit Exploded Views and Parts

Diagrams and parts lists for various outdoor unit models.

Wiring Diagram

Indoor Unit Electrical Wiring

Electrical circuit diagrams detailing indoor unit connections.

Outdoor Unit Electrical Wiring

Electrical circuit diagrams detailing outdoor unit connections.

Schematic Diagram

Indoor Unit Circuit Schematics

Detailed circuit schematics for indoor unit components.

Outdoor Unit Circuit Schematics

Detailed circuit schematics for outdoor unit components.

PCB Diagram

Indoor Unit Main PCB Layout

Identifies components and connectors on the indoor main PCB.

Outdoor Unit Main PCB Layout

Identifies components and connectors on the outdoor main PCB.

Indoor Unit Sub PCB Layout

Identifies components and connectors on the indoor sub PCB.

Troubleshooting

Initial Troubleshooting Checklist

Essential preliminary checks before diagnosing issues.

Installation Testing Procedures

Verification tests to ensure correct installation.

Symptom-Based Fault Diagnosis

Flowcharts for diagnosing problems based on observed symptoms.

PCB Inspection and Replacement

Guidelines for inspecting and replacing PCB components.

Reference for Installation

Installation Area Selection Guide

Guidelines for choosing optimal installation locations for units.

Connecting and Purging Circuit

Procedures for connecting refrigerant pipes and purging air.

Refrigerant Refill Procedure

Steps for refilling refrigerant after installation or leak.

Refrigerant Adjustment by Pipe Length

Adjusting refrigerant based on connection pipe length.

Flare Nut Fixing Torque

"Pump down" Procedure

Reference Information

Model Name Decoding Index

Explains the structure and meaning of model names.

Refrigeration Cycle Diagrams

Visual representation of the refrigeration cycle for different models.

Pressure and Capacity Unit Conversion

Conversion table for pressure and capacity units.

Technical Terms Glossary

Definitions of commonly used technical terms in the manual.

Troubleshooting FAQ

Frequently asked questions regarding non-trouble issues.

Basic Refrigeration Principles

Fundamental concepts and principles of refrigeration.

GSPN (Global Service Partner Network)