38
Temp Control &Operation Functions
No Description OthersError
1
2
3
4
5
6
7
8
9
10
F-SENSOR ERROR
R-SENSOR ERROR
F-DEFROST SENSOR ERROR
R-DEFROST SENSOR ERROR
ICE MAKER SENSOR ERROR
AMBIENT SENSOR ERROR
F-DEFROST HEATER ERROR
R-DEFROST HEATER ERROR
ICE MAKER FUNCTION ERROR
U-ART TELECOM ERROR
Fault rated F-SENSOR?
Fault rated R-SENSOR?
Fault rated F-DEFROST SENSOR?
Fault rated R-DEFROST SENSOR?
Fault rated ICE MAKER SENSOR?
Fault rated AMBIENT SENSOR?
Fault rated F-DEFROST?
Fault rated R-DEFROST?
Fault ICE MAKER OPERATION?
Fault SENSOR?
LED Display
- Self Diagnosis Check List
2) Self-diagnosis with initial power on
2-1) When pressing the Super Freeze button and the Super Cool button simultaneously for 6 sec during
normal operation, the entire temperature setting display will blink for 2 sec at the interval of 0.5 sec and
when pressing the Super Cool button and the Super Cool button simultaneously for 8 sec including 2 sec
blinking, self-diagnosis will be selected.
2-2) It goes into the Self Diagnosis function with a “Ding-Dong” sound and it shows error codes on the LED
display.And then,it will be restored to the normal operation.
2-3) During self-diagnosis,button inputs will not be recognized but only the canceling buttons.