64
TROUBLESHOOTING
7) If Ice Room Sensor has trouble
Bad contact of connector/ insert correctly
Is MAIN PCB
ConnectorCN31 and CN76
inserted correctly?
Is Ice Room Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN31#3 (Orange) and
REG1, HEAT SINK normal?
Is the input voltage of
IC01 MICOM #71 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the contact of PCB & Wire
Terminal correctly.
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder bridging,
disturbed solder. Replace the PCB
NO
No trouble with PCB and temperature sensor.
Check the bad connections.
** Measuring point of resistance value according to
Sensor **
Ambient : CN31#3 CN76#1 Measure the resistance
value
** 0: Short trouble / ∞Ω: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #77,
CN30-"4"(Orange) and REG1, HEAT SINK from PCB
typical Ground part are similar.
Check the measure on the SENSOR MARKING
#8(R308) due to the SMD MICOM
Checking Mehod of Ice Room Sensor voltage
CN31-”3”(Orange) CN76-”1” (Gray)
- Compare with the temperature table after
measurement.
DATA1.
Temperature table
ERROR Code
Refer to the circuit diagram in this manual
Ice Room
Connector Cn31#3(Orange) to REG1
HEAT-SINK PCB common Ground
Checking method of Ice Room Sensor voltage
- Measure the voltage of Sensor Check Point #8
(IC01 MICOM #71) on PCB or CN31#3(Orange) REG1, HEAT SINK
- Compare the temperature table after measurement. Measuring
voltage of CN31#3(Orange) REG1, HEAT SINK are as below
typical PCB Ground
REG1 HEAT-SINK
2¢(-17¡) is recommended 38¢(3¡) is recommended
Start
YES
YES
YES
AW-SEM Transform(RF267,2#3957D8 2009.8.20 4:54 PM 6 4 i n