8) If Pantry Sensor has trouble
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN30 and CN76 insert
correctly?
Is Pantry Sensor
normal?
Is the voltage between
MAIN PCB Connector CN30#9 (White-black) and
REG1, HEAT SINK normal?
Is the input voltage of IC01
MICOM Pin #73 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the contact of PCB & Wire
Terminal correctly.
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder bridging,
disturbed solder. Replace the PCB
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
** Measuring point of resistance value according to
Sensor **
Pantry : CN30#9 CN76#1 measuring resistance
value
** 0: Short trouble / ∞Ω: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage of IC01 MICOM #73,
CN30-"9"(White-black) and REG1, HEAT SINK from
PCB typical Ground part are similar.
Check the measure on the SENSOR MARKING
#6(R314) due to the SMD MICOM
Checking method of Pantry Sensor resistance
CN30#9(White-black) CN76#1(Gray)
-
Compare the temperature table after the measure
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
Pantry
Connector Cn30#9(White-black) to REG1
HEAT-SINK PCB common Ground
Checking method of Pantry Sensor voltage
- Measure the voltage of Sensor Check Point #6(IC01 MICOM #73) on
PCB or CN30#9(White-black) REG1, HEAT SINK
- Compare the temperature table after measurement. Measuring voltage
of CN30#9(White-black) REG1, HEAT SINK are as below
typical PCB Ground
REG1 HEAT-SINK
2¢(-17¡) is recommended 38¢(3¡) is recommended
Start
YES
YES
YES
AW-SEM Transform(RF267,2#3957D8 2009.8.20 4:54 PM 6 5 i n