EasyManua.ls Logo

Samsung RNS24ABT - Installation Guide; Typical Installation Overview

Samsung RNS24ABT
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
51
11. Installation
Viewing the typical installation
A typical installation will be similar to the one shown below.
Evaporator/fancoil (indoor)
Maximum pipe height
Maximum pipe length
Refrigerant lines,
electric, and drain
Compressor/condenser(outdoor)
Unit : ft (m)
Model
Pipe length Pipe height
Minimum Maximum
Standard for factory
charge
Maximum
**09*******
**12*******
9.8 (3) 65.6 (20) 24.6 (7.5) 49.2 (15)
**18*******
**24*******
9.8 (3) 98.4 (30) 24.6 (7.5) 65.6 (20)
CAUTION
Outdoor Unit
Outer wall
Indoor Unit
Cut insulation to have
rainwater drained
Make a U-trap (A) on the pipe (which is
connected to the indoor unit) at outer wall
and cut the bottom part of the insulation
(about 10 mm) to prevent rainwater from
getting inside through the insulation.
CAUTION