11. Installation
54
Sea breeze
Sea breeze
Sea
Sea
Outdoo r
unit
Outdoo r
unit
Outdoo r
unit
Sea breeze
Protection wall
Sea
Outdoo r
unit
Outdoor unit
Protection wall should be constructed with a solid material that
can block the sea breeze and the height and width of the wall
should be 1.5 times larger than the size of the outdoor unit. (You
must secure more than 2296.6 ft (700 mm) of space between
the protection wall and the outdoor unit for air circulation.)
Minimum clearances for the outdoor unit
Legends:
Wall
Minimum clearance in mm
23.6
(600)
11.8
(300)
Air flow direction
Top view Side view
Examples for installing one outdoor unit:
Unit: inch (mm)
11.8
(300)
59
(1500)
11.8
(300)
5.9
(150)
23.6
(600)
78.74
(2000)
59
(1500)
19.6
(500)
11.8 (300)
59
(1500)
11.8
(300)
Examples for installing multiple outdoor units:
Unit: inch (mm)
59
(1500)
23.6
(600)
118.11
(3000)
118.11
(3000)
7. 8 7
(200)
23.6 (600)
23.6 (600)
59
(1500)
11.8
(300)
59
(1500)
11.8
(300)
11.8
(300)
23.6
(600)
23.6
(600)
23.6
(600)
19.6
(500)
11.8 (300)
11.8 (300)
19.6
(500)