EasyManua.ls Logo

Samsung RSG5F series - Test Function for SRG5 B** Models

Samsung RSG5F series
111 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48
RSG5K/F/D***, RSG257AA**
Press the Power Freeze and the Fridge buttons for more than 8 seconds at the same time.Then, the
Freezer & Fridge temperature display will be turned off and the Test mode begins.
RSG5BL**
Press the Freezer temp and the Child Lock buttons for 6 seconds at the same time and then Panel
display blinks for 4 seconds at an intervals of 0.5 sec. During this time, press the Child Lock Button and
then panel display will be off and Test mode begins.
With the Inverter Comp model, when you press the Test button (Power Freeze, Lighting, Freezer,
Fridge KEY), the Test function will be selected in the following order.
Forced Operation 1 (FF 1)
Forced Operation 2 (FF 2) Forced Operation 3 (FF 3)
Forced Fridge/Freezer Defrost (Fd) Cancelled (Normal Operation)
The recommended way to cancel the Test function is turning off an on the unit.
TROUBLE SHOOTING
4-1-1) Test Function (Forced Operation / Forced Defrost)
Press the Power Freeze and the Fridge buttons for 8 seconds at the same time.
Press the Freezer temp and the Child Lock buttons for 6 seconds at the same time.
RSG5K/F/D*
RSG5B*
RSG257*

Table of Contents

Related product manuals