50
RSG5V**
Press the Power Freeze and the Fridge buttons for more than 8 seconds at the same time.Then, the
Freezer & Fridge temperature display will be turned off and the Test mode begins.
With the Inverter Comp model, when you press the Test button (Power Freeze, Lighting, Freezer,
Fridge KEY), the Test function will be selected in the following order.
Forced Operation (FF)
R off Forced Operation(OF r) Forced Fridge Defrost(rd)
Forced Fridge/Freezer Defrost (Fd) Cancelled (Normal Operation)
The recommended way to cancel the Test function is turning off an on the unit.
TROUBLE SHOOTING
4-1-2) Test Function (Forced Operation / Forced Defrost)
Press the Power Freeze and the Fridge buttons for 8 seconds at the same time.