15
Outdoor units
*1) Mode
HP : Heat Pump, HR : Heat Recovery
*2) Norminal cooling capacities are based on;
Indoor temperature : 26.7°C DB, 19.4°C WB(80°F DB, 67°F WB)
Outdoor temperature : 35°C DB, 23.9°C WB(90°F DB, 75°F WB), Equivalent refrigerant piping : 7.6m(25ft) , Level differences : 0m(0ft)
*3) Norminal heating capacities are based on;
Indoor temperature : 21.1°C DB, 15.6°C WB(70°F DB, 60°F WB)
Outdoor temperature : 8.3°C DB, 6.1°C WB(47°F DB, 43°F WB), Equivalent refrigerant piping : 7.6m(25ft) , Level differences : 0m(0ft)
*4) Sound level was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
*5) Specifications are subject to change without prior notice for product improvement.
Type
Model Name RVXVHT150FE RVXVHT175FE
Model Basic
RVXVHT075FE
2
1
RVXVHT100FE
1
RVXVHT125FE
Power Supply Ø/ V/ Hz
3/ 208~230/ 60 3/ 208~230/ 60
Mode
1)
-
Heat Pump Heat Pump
Performance
US Ton TON
12 14
Horse Power HP
15.0 17.5
Nominal
Capacity
Cooling
2)
Btu/h
144,000 168,000
US RT
12.0 14.0
Heating
3)
Btu/h
162,000 189,000
US RT
13.5 15.8
Power
Nominal Input
Cooling
kW
11.0 13.0
Heating
10.3 12.2
Nominal Running
Current
Cooling
A
37.6 47.7
Heating
45.2 47.5
Circuit Breaker (MCCB/ELB/ELCB) A
50 + 50 50 + 50
COP
Cooling -
3.84 3.79
Cooling (US Only) Btu/Wh
13.09 12.92
Heating -
4.61 4.53
Compressor
Model
ZPJ72* ZPJ83* ZPI61* ZPI83* ZPJ72* ZPJ83* ZPI61* ZPI83*
Type -
DVI Scroll FVI Scroll DVI Scroll FVI Scroll
Number EA
2 2 2 2
Piston Displacement
cc/Rev
67.1 58.1 67.1 58.1
in³/Rev
4.095 3.545 4.095 3.545
Output kW
6.94 5.83 6.94 5.83
Lubricant
Type -
3MAF POE 3MAF POE
Charging
cc
1,685 1,685 1,685 1,685
fl. oz.
57 57 57 57
Fan
Type / Control -
Propeller/BLDC Propeller/BLDC
Motor Output W
(630) x 2 (630) x 2
Airflow Rate
m
3
/min
(170) x 2 (170) x 2
CFM
(6004) x 2 (6004) x 2
External Static
Pressure
Max.
Pa
78.5 78.5
WG
0.315 0.315
Safety
Devices
Mechanical Type
-
High Pressure Switch High Pressure Switch
-
Comp./Accum. Crank Case Heater Comp./Accum. Crank Case Heater
-
Fuse for PCB Fuse for PCB
Electronic Type
-
Over-voltage Protection Over-voltage Protection
-
Current Transformer Current Transformer
-
Fan motor Voltage Protection Fan motor Voltage Protection
Piping
Connections
Liquid
Ø, mm
12.70 15.88
Ø, inch
1/2 5/8
Gas
Ø, mm
28.58 28.58
Ø, inch
1 1/8 1 1/8
Oil (Flare)
Ø, mm
6.35 6.35
Ø, inch
1/4 1/4
Installation
Limitation
Max. Length
m
200 200
ft
656 656
Max. Height
m
50 (40) 50 (40)
ft
164 (131) 164 (131)
Refrigerant
Type -
R410A R410A
Factory Charging
kg
(6.5) x 2 (6.5) x 1 + (7.5) x 1
lbs
(14.33) x 2 (14.33) x 1 + (16.53) x 1
Sound
4)
Sound Pressure dB(A)
60 61
Set Size
Net Weight
kg
(240) x 2 (240) x 2
lbs
(529) x 2 (529) x 2
Shipping Weight
kg
(253) x 2 (253) x 2
lbs
(558) x 2 (558) x 2
Net Dimensions (WxHxD)
mm
(880 x 1668 x 765) x 2 (880 x 1668 x 765) x 2
inch
(34 5/8 x 65 5/8 x 30 1/8) x 2 (34 5/8 x 65 5/8 x 30 1/8) x 2
Shipping Dimensions (WxHxD)
mm
(948 x 1888 x 832) x 2 (948 x 1888 x 832) x 2
inch
(37 3/8 x 74 3/8 x 32 3/4) x 2 (37 3/8 x 74 3/8 x 32 3/4) x 2
Cable
Main Power (Below 50m) AWG #
Separate electrical connection for each outdoor units Separate electrical connection for each outdoor units
Communication AWG #
AWG 16~18 AWG 16~18
Operating
Temp. Range
Cooling
°C
-5~46.1 -5~46.1
°F
23~115 23~115
Heating
°C
-20~24 -20~24
°F
-4~75 -4~75