Whenmakingacontrolsystemtocontrolthecamera,pleaseusetotheprotocol
SAMSUNG-T,SAMSUNG-E,PELCO-P,PELCO-D,VICON,PANASONIC,BOSCH,HONEYELL).
•WhenyouconnectingtoRS-485CONTROLTERMINAL,pleasepeelofftheouter
skininsidetheRS-485CONTROLTERMINAL.
•
IncaseofSCC-101connection,changecommunicationmodeto8-E-1at Communication
configurationmenu.(Formoreinformation,refertoSCC-101manual.)
Notes
Using Coaxial Communications
• Coaxial Communications System
• OSD Control method
DVR
Distance
Recommended Cable Specification
300m 3C2V(RG-59/U)
450m 5C2V(RG-6/U)
600m 7C2V(RG-11/U)
– Video Cable
The camera's video output port is connected to the monitor with a BNC coaxial cable,
shown below : If the distance between the camera and the monitor exceeds the
recommended maximum, please use an auxiliary video amp.
•If the cameraiscontrolled through coaxialcommunication,please use avideo
amp intended forcoaxial communications. Regular video ampsdo not transfer
coaxial signals.
Notes
Using RS-485 communication will enable you to control the OSD menu from a SAMSUNG
TECHWIN System Controller or DVR.
(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX) SERIAL PORT OF THE PC(COM1) → SERIAL CABLE → RS-485 CONVERTER → RS-485
CONTROL CABLE
Connecting to RS-485 Control Cable
CONTROL CABLE SPEC
WHITE (TRX+) RS-485+
BLUE (TRX-) RS-485-
* RS-485 Communication establishment initial value
485 Control Board Connection Port RS-485 Control Port
(+) CONNECTION TERMINAL WHITE (TRX+)
(-) CONNECTION TERMINAL BLUE (TRX-)
Item
Camera ID BAUD RATE UART MODE RET PKT
Initial value
1 9600 8-NONE-1 ENABLE
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
WHITE (TRX+)
BLUE (TRX
-
)
CAMERA DVR CONTROLLER
SET MENU/ENTER OSD KEY
UP UP KEY JOYSTICK UP
DOWN DOWN KEY JOYSTICK DOWN
LEFT LEFT KEY JOYSTICK LEFT
RIGHT RIGHT KEY JOYSTICK RIGHT
RS-485 communication control
Connection
•
:BNC
•
---- :RS-485