4.AlignmentandTroubleshooting
4.2.3.Imagequalityproblem
1)VerticalBlackLineandBand
Description:Straightthinblackverticallineoccursintheprintedimage.
CheckandcauseSolution
•Damageddeveloprollerinthetonercartridge.
DeformedDoctor-bladeorcleaning-blade.
•Scratchedsurfaceofthechargerollerinthetoner
cartridge.
Replacethetonercartridge.
Partlydepressionordeformationonthesurfaceofthe
transferroller.
Replacethetransferroller.
2)VerticalWhiteLine
Description:Whiteverticalvoidsoccursintheprintedimage.
CheckandcauseSolution
Foreignmatterstucksontothewindowofinternallensesof
LSUmirror.
CleantheLSUwindowwithrecommendedcleaner(IPA).
Cleanthewindowwithacleancottonswab.
ThelifeofthetonercartridgehasbeenexpiredReplacethetonercartridge.
Someforeignsubstancesareonthewindowofthetoner
cartridgeframe.
Removetheforeignmatteroftheexposurewindow.
Ifthefuserisdefective,voidsoccurperiodicallyatthetop
ofablackimage.
Reinstallthefuserunit.
Copyright©1995-2011SAMSUNG.Allrightsreserved.4-43