62 | SAMSUNG
FEATURES & OPERATION
6
6-4. Temperature and Humidity Ranges
●
The following table indicates the temperature and humidity ranges within which the air conditioner can be used.
Temperature and Humidity Ranges
If the air conditioner is used at... Then...
High temperatures The automatic protection feature may be triggered and the air conditioner
stopped.
Low temperatures A water leakage or some other malfunction may happen if the
heat exchanger freezes.
High humidity levels Water may condense on and drip from the surface of the indoor unit
if it is used for long periods.
Mode Outdoor Temperature Indoor Temperature Indoor Humidity
Heating 0°C to 24°C approx. 27°C or less -
Cooling 21°C to 43°C approx 18°C to 32°C approx. 80% or less
Drying 18°C to 43°C approx. 18°C to 32°C approx. -
❇ If the heating operation is used at below 0°C(outdoor temperature) then, does not have a full capacity.
If the cooling operation is used at over 33°C(indoor temperature) then, does not have a full capacity.