30 | SAMSUNG
INSTALLATION
5
Selecting Area for Installation (cont.)
5-1-2. Outdoor Unit
1. Make sure that you install the outdoor unit in area not exposed to the rain or direct sun light.(Install a separate sunblind if exposed to
direct sun light.)
2. Make sure that you install the outdoor unit in area allowing the good air moment, not amplifying noise or vibration, especially to avoid
disturbing neighbors. (Fix the unit firmly if it is mounted in a high place.)
3. Make sure that you install the outdoor unit in area providing the good ventilation and which is not dusty. It must not be blocked by any
obstacle affecting the airflow near the air inlet and the air outlet.
4. Make sure that you install the outdoor unit in area free from animals or plants.
5. Make sure that you install the outdoor unit in area not blocking the traffic.
6. Make sure that you install the outdoor unit in area easy to drain condensed water from the indoor unit.
7. Make sure that you install the outdoor unit in area which provides easy connection within the maximum allowable length of a coolant
pipe.
8. Make sure that you install the outdoor unit in an area which is large enough to accommodate the measurements shown in figure on the
next page.
5-1-3
. Remote Control Unit
1. Make sure that you use the remote control unit in an area free from obstacles such as curtains etc, which may block signals from the
remote control unit.
2. Make sure that you put the remote control unit in an area not exposed to direct sunlight, and where there is no source of heat.
3. Make sure that you use the remote control unit in an area away from TVs, audio units, cordless phones, fluorescent lighting fixtures and
other electrical appliances (at least 1 meter).
MODEL
SH07 / 09A✳✳
SH12A✳✳
A
7.5
7.5
B
20
30
If you have used...
More than "A" metres of
piping
"B"g of refrigerant (R410A)
must be added for each
extra meter.
Less than "A" metres
of piping
The purge time is normal.
Then...