Adjustment
5-7 PUNT ADJ
■ Adjustment objective: After replacing the MAIN PCB and BARREL, you must decide the AF search range so that the optimal
focuscanbeidentiedbythebodytube.
■ Necessary equipment: InnityCallimator
<Adjustment method>
1. Save the adjustment le to the microSD™ card and install it on the camera.
2. Refer to the following adjustment environment specication to adjust the focus.
1) Used specication of Innity Callimator
-SettheilluminancespecicationoftheCallimatorto6LV.
-Maintaindistanceoflessthan1cmbetweentheendofthecamerabodytubetothelenssurfaceoftheInnityCallimator.
-Thecameramustbexedwhiletheadjustmentismade.
2) Used specication for innite object
-Thecameramustbexedwithatripodandleveledconditionmustbemaintained.
-Setupthecameratowardabuildingorobjectininnitedistance(morethan500m).(Donotusethechart)
- Set a cathedral, partment or object with high contrast in day environment/AF area display.
Fig. 5-4
Innity Callimator
Camera
Tripod