4-2
4. Troubleshooting
4-2. No Power
Symptom
When turning on the Power button after connecting the power, the LED at the front of the
monitor does not operate.
-
Major
checkpoints
Check the IP board power fuse and the IP board output power.
Check the connections for the IP board and the Main board inside the monitor.
Check the Main board power part and check also whether there is any abnormal output at other
output terminals.
-
-
-
Diagnostics
Yes
Check function assy.
Yes
Replace IP board.
No
When Pin 4 of CN600 is 0V,
Does proper DC 14V appear at pin 5 of
CN600?
When Pin 1 of IC 702 is DC 14V,
Does proper DC5V appear at pin1 of
IC601
Check IC 701 and related
circuit.
No
Yes
Check IC 601 and related
circuit.
No
When pin 1 of IC 601 is DC 5V,
Proper DC 3.3V appear at pin 3 of IC
601
Yes
Check IC 602 and related
circuit.
No
When pin 3 of IC 602 is DC 5V,
Proper DC 1.8V appear at pin 2 of IC
602
Caution Make sure to disconnect the power before working on the IP board.
Main Board Front