EasyManua.ls Logo

Samsung SyncMaster 2032BW - No Video (DVI) Troubleshooting

Samsung SyncMaster 2032BW
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-5
4. Troubleshooting
4-4. No Video (DVI)
Symptom - The LED power turns on but the screen is blank when the DVI cable is connected.
Major
checkpoints
- Check the DVI cable connections.
- Check whether the LVDS cable is connected correctly to the panel.
- Check whether the lamp connector of the panel is connected correctly to the IP board.
Diagnostics
Yes
1
Check signal cable connection
and power.
Yes
Replace or check related
circuit.
No
X1 oscillate properly?
Is there R, G, B input at
R100,R101,R102,R106
and R108?
Check input part.
No
Yes
Does the output signal appear
at Pin 17~20, 22~27 of CN400?
Check IC400 and related
circuit.
No
Yes
There are DC 5V at Pin 1,
2 and 3 of CN400?
Check the PANEL_EN signal
at R222 and BL_EN signal at
R603.
No
Yes
Replace LCD Panel.
4
5
6
Caution Make sure to disconnect the power before working on the IP board.
Main Board Front