holly53Aug 22, 2025
What to do if my Samsung UH052EAS shows a power cable connection error?
- CCarol CurtisAug 22, 2025
If your Samsung Air Conditioner displays a power cable connection error, you should check the status of the power connection.
What to do if my Samsung UH052EAS shows a power cable connection error?
If your Samsung Air Conditioner displays a power cable connection error, you should check the status of the power connection.
What to do if my Samsung Air Conditioner displays a '[inverter] IPM over cur- rent error'?
If your Samsung Air Conditioner displays an inverter IPM over current error, check if refrigerant is filled, verify the connection status of the compressor and ensure it operates normally, and check for any obstacles around the indoor/outdoor units.
What to do if my Samsung Air Conditioner displays a '[inverter] Compressor rotation error'?
If your Samsung Air Conditioner displays an inverter compressor rotation error, check the connection status of the compressor and the resistance between different phases in the compressor.
What to do if my Samsung Air Conditioner displays a '[inverter] Compressor operation error'?
If your Samsung Air Conditioner displays an inverter compressor operation error, check the connection status of the compressor and the resistance between different phases in the compressor.
What to do if my Samsung UH052EAS displays a 'Discharge current error/ PFC over-current error'?
If your Samsung Air Conditioner displays a discharge current error or PFC over-current error, check the input power, ensure refrigerant is filled, and verify the outdoor fan operates normally.
What to do if my Samsung Air Conditioner showing outdoor fan 2 error?
If your Samsung Air Conditioner displays an outdoor fan 2 error, check the connection status of input power, the connection status of the motor and outdoor PCB, and the fuse of the indoor/outdoor unit.
What to do if my Samsung UH052EAS showing outdoor fan 1 error?
If your Samsung Air Conditioner displays an outdoor fan 1 error, check the input power connection status, the connection between the motor and PCB in the outdoor unit, and the fuse of the indoor/outdoor units.
What to do if my Samsung UH052EAS displays a gas leakage error?
If your Samsung Air Conditioner displays a gas leakage error, verify that the refrigerant is filled and check the indoor EVA sensor.
What to do if my Samsung UH052EAS showing outdoor temperature sensor error?
If your Samsung Air Conditioner displays an outdoor temperature sensor error, check the connection status of the sensor, its location, and the resistance values of the sensor.
Brand | Samsung |
---|---|
Model | UH052EAS |
Category | Air Conditioner |
Language | English |
Lists key features of the air conditioner, including easy installation, high performance, long piping, and eco-friendly design.
Guidelines for safe and proper installation of the air conditioner.
Technical specifications and performance data for the air conditioner models.
Step-by-step instructions for disassembling the indoor unit.
Electrical wiring diagram for the indoor unit.
Layout and component identification for the indoor unit's PCB.
Explanation of buttons and display elements on the wireless remote controller.
Initial checks and common issues before detailed troubleshooting.
Step-by-step guide to diagnose faults based on observed symptoms.
Procedures and guidelines for installing the air conditioner.