4-2-6. T-CON Board
T-CON Operation and Testing
Check TV Board Connector Voltages from SMPS (switched voltages on CNM803)1.
Test for 13VDC at both sides of both fuses on the TCON Board.2.
If either one of the fuses is open, replace the T-CON Board.3.
If 13VDC are missing on fuses, check output feed from TV Board (CN501,pins 1-10).4.
If 13VDC feed is present at the output of the TV Board, suspect a defective LVDS cable.5.
If the 13VDC feed is not present, suspect a defective TV Board or SMPS.6.
CN201 (POWER Connector)
1 GND 9 A13V_PW 17 A13VS_PW
2 GND 10 OVD_ON_OFF 18 GND
3 A13V_PW 11 SMPS_FET_FAIL_DETECT 19 A13VS_PW
4 GND 12 ANA_DIMMING 20 GND
5 A13V_PW 13 GND 21 A13VS_PW
6 SW_POWER_OUT 14 OVD_LEVEL 22 GND
7 A13V_PW 15 A13V_PW
8 B5V_PW 16 GND
(ASSY T CON P)
Fuse
CN501
CN201
CN2301
CNM803
CNM803 from SMPS