EasyManua.ls Logo

Samsung WA45M3100A Series - Page 27

Samsung WA45M3100A Series
35 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting _ 25
Symptom Check Code Countermeasure Troubleshooting Procedure Measurement Picture
Switch Code
(Panel-Sub PBA)
Eco Warm
LED Flash
The Power button is
continually pressed.
A button other than the
Power button is continually
pressed.
Check whether either the Power switch or a
tact switch is continually pressed.
Check whether the service PBA holding
screws are fastened too tight. If they are
fastened too tight, loosen them a little.
If the main PBA switching IC on/off Code has
occurred, replace the main PBA.
The“EcoWarmLED”f ashesifthemain
relay connections are incorrect. Check the
connections.Ifthereisnof ashinginthe
connections, replace the main PBA.
Check beep sound, when pressing button
- sound on : Panel fault -> Check
connections, still same, change a panel
- no sound : Main PBA fault -> Check
connections, still same, change a Main PBA
Check the contact between the
control panel buttons and their
corresponding tact switch.
- There must be a gap between a
control panel button and its
corresponding micro switch.
Otherwise, an Code occurs
afterapprox.30secondshas
passed.

Other manuals for Samsung WA45M3100A Series

Related product manuals