Troubleshooting _ 25
Symptom Check Code Countermeasure Troubleshooting Procedure Measurement Picture
Switch Code
(Panel-Sub PBA)
►
Eco Warm
LED Flash
The Power button is
continually pressed.
A button other than the
Power button is continually
pressed.
•
•
Check whether either the Power switch or a
tact switch is continually pressed.
Check whether the service PBA holding
screws are fastened too tight. If they are
fastened too tight, loosen them a little.
• If the main PBA switching IC on/off Code has
occurred, replace the main PBA.
• The“EcoWarmLED”f ashesifthemain
relay connections are incorrect. Check the
connections.Ifthereisnof ashinginthe
connections, replace the main PBA.
• Check beep sound, when pressing button
- sound on : Panel fault -> Check
connections, still same, change a panel
- no sound : Main PBA fault -> Check
connections, still same, change a Main PBA
Check the contact between the
control panel buttons and their
corresponding tact switch.
- There must be a gap between a
control panel button and its
corresponding micro switch.
Otherwise, an Code occurs
afterapprox.30secondshas
passed.