Troubleshooting _ 25
Symptom Error Code Countermeasure Troubleshooting Procedure Measurement Picture
Door Error
►dC
This may occur when the
door switch is defective.
This may occur when the
main PCB is defective.
• Check if a dE error occurs during the boiling
course.
• As this error occurs because the door is
opened,closethedoor.
• Since120Vpowerisconnected,checkif
the power cord is disconnected or check the
insulation status and repair it if necessary.
• If the main PBA door detection circuit is
defective,replaceit.
1. Check the resistance for Reed
SW (Checking Part :White-
Green Wire)
- Resistance:Approx0.2Ω
between the terminals of
Reed SW.
2. Check the resistance for Motor
(Checking Part : Black-Brown
Wire)
- Resistance:33Ωto46Ω
between the terminals of Motor.
►dC1
The door lock switch unit is
not inserted.
The door lock switch unit is
damaged.
The wire is disconnected.
The door lock switch unit is
defective.
This may occur due to a
defect of the main PCB.
• Check whether the door lock switch unit is
inserted.
• Check whether the door lock switch unit is
damaged.
• Check the disconnection of the wire.
• Ifthedoorlockswitchunitisdefective,
replace it.
• IfthemainPCBisdefective,replaceit.
3. Check the resistance for Lock/
Unlock Contact
(Checking Part : Lock White-
Red Wire Unlock White-Blue
Wire)
- Resistance: Resistance:
Approx0.2Ωbetweenthe
terminals of Contact.
Check the Door Lock/Unlock
state.
Switch Error
(Main Relay
Error)
►bC2
The Power button is
continually pressed.
A button other than the
Power button is continually
pressed.
• Check whether either the Power switch or a
tact switch is continually pressed.
• Check whether the service PBA holding
screws are fastened too tight. If they are
fastenedtootight,loosenthemalittle.
• IfthemainPBAswitchingICon/oerrorhas
occurred,replacethemainPBA.
• The “E2” error occurs if the main relay
connections are incorrect. Check
theconnections. If there is no error in the
connections,replacethemainPBA.
Check the contact between the
control panel buttons and their
corresponding tact switch.
- There must be a gap between
a control panel button and
itscorresponding micro switch.
Otherwise,anerroroccurs
afterapprox.30secondshas
passed.