26 _ Troubleshooting
Symptom Error Code Countermeasure Troubleshooting Procedure Measurement Picture
Water Leakage
Error
►LC
This may occur when an
alien substance is in the DV
Case.
• Since this occurs when an alien substance is
intheDrainingBellows,fornaturaldraining,
remove the alien substance.
• Ifthedrainmotorisdefective,replacethe
motor.
• Check if the water leaks from the tub
connection part.
Check if there is any alien
substance in the Draining Bellows.
Check if there is any alien
substance such as underwear
wire,coins,etc.
This may occur due to a
defect of the product’s
internal hose or from the part
assembly.
Unbalance Error
►UC
This may occur due to the
laundry being unevenly
distributed.
• Check the laundry type and check if the
laundry load is unbalanced.
- Make sure to check if there is any laundry
present that absorbs a lot of water even if
itsvolumeissmallandexplaintheproblem
comprehensively,ifnecessary.
-
Mems PBA
Detected
►8C
►8C1
►8C2
This may occur due to
disconnection.
• Check wire connections.
This may occur when the
Mems PBA is defective.
• Replace the Mems PBA.
• Replace Mems PBA because of the main
PBA wire disconnection error or PBA silver
nano part malfunction.
OverowError ►OC
This may occur when the
water level sensor is
defective.
This may occur when water
is supplied continuously
due to freezing or foreign
materials in the water
supply valve.
• The water level sensor is replaced.